工业废水处理设备的日常维护与调试 |
添加时间:2018/9/15 16:44:02 浏览次数: |
1、调试:污水泵按额定流量把污水抽水设备内,启动风机进行曝气,每天观察接触池内填料情况,如填料上长出橙黄或黑色的一层膜,这一过程一般要7-15天。如是工业有机废水最好先用生活污水培养好生物膜后,再逐渐引入工业污水进行生物膜训化。
1, commissioning: the sewage pump starts the fan to aerate
according to the rated flow volume, and aeration is observed. The filler
in the contact pool is observed every day, such as orange or black film
on the packing, which usually takes 7-15 days. For example, industrial
organic wastewater is better to use domestic sewage to cultivate
biofilm, and then gradually introduce industrial sewage for biological
membrane training.
2、设备维护保养:该工业废水处理设备必须建立一套定期保养制度。主要易损部件是风机与水泵电动设备的转向不得接反。一旦污水进入风机,必须及时清理,更换机油后方可使用。风机启动前必须注意空气闸门是否打开。风机每运行10000小时必须保养一次。水泵每运行5000-8000小时必须保养一次。
2, equipment maintenance: the industrial wastewater treatment
equipment must set up a set of regular maintenance system. The main
vulnerable parts are that the steering of the fan and the electric
equipment of the pump shall not be reversed. Once the sewage enters the
fan, it must be cleaned in time, and the oil can be used after the
replacement of the oil. Before the fan is started, it is necessary to
pay attention to the opening of the air gate. The fan must be maintained
once every 10000 hours. The pump must be maintained once every
5000-8000 hours.
|